EasyManua.ls Logo

Lenze L-force 9400

Lenze L-force 9400
646 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories (overview)
Filters
Sinusoidal filters EZS3−xxxA200 115 ... 150 A
8
610
EDS94SPP101 EN 10.2
Electrical installation
M
3~
1U1
1U2
1V1
1V2
1W1
1W2
EZS3-xxxA200
xxxx
UVW
SSP94SF107 SSP94SF004
Terminal data
Sinusoidal filter
Terminal PE screw
Connection cross−sections Tightening torque Tightening torque
[mm
2
] [AWG] [Nm] [lb−in] [Nm] [lb−in]
EZS3−115A200
35 ... 95
4/0 ... 2 6 53.1 M8 18 159.3
EZS3−150A200
Safety instructions for the installation according to UL/CSA
Original − English
Warnings!
Conditions of Acceptability:
ƒ The products covered by this report are only intended for use with Power
Conversion Equipment (inverters).
ƒ Appropriate cooling measures shall be taken based on the power loss data
within the instructions available from the manufacturer.
ƒ External wiring material for models with bus bar screw connectors − R/C
(AVLV2), rated 105 °C min., suitable for applied voltage and current. If wiring
material with a lower temperature rating is used, an additional temperature
test at the wiring material has to be conducted in the end use.