Accessories (overview)
General accessories
Power supply unit
8
635
EDS94SPP101 EN 10.2
Connection plan
L
N
PE
+
+
-
-
DC OK
13
14
DC 22.5
28.5 V
AC 85
264 V
1
ezv1200_07
Potentiometer
At DC OK: 24 V, max. 40 mA
L1
L2
L3
PE
+
+
-
-
DC OK
13
14
DC 22.5
28.5 V
3 AC 320
575 V
2
ezv4801_07
Potentiometer
At DC OK: 24 V, max. 40 mA
Terminal data
Input terminals Output terminals
Rigid terminal 0.2 ... 2.5 mm
2
(AWG 24 ... 12)
0.2 ... 2.5 mm
2
(AWG 24 ... 12)
Flexible terminal with
wire end ferrule with
plastic collar
0.2 ... 2.5 mm
2
(AWG 24 ... 12)
0.2 ... 2.5 mm
2
(AWG 24 ... 12)
Stripping length 7 mm 7 mm
Tightening torque 0.5 ... 0.6 Nm
(4.4 ... 5.3 lb−in)
0.5 ... 0.6 Nm
(4.4 ... 5.3 lb−in)