Current requirement of 24−V supply
[mA][mA]ConnectionGGType
Connections
Keypad EZAEBK... X6 50 5 250
Digital outputs X4 70 6 420
Analog outputs X3 10
Memory modules (MMI)
MMxxx E94AYM... 20 5 100
Feedback
Encoder X8 110
Resolvers X7 20 5 100
Communication (MXI1/MXI2)
CANopen® E94AYCCA X 30
DeviceNet E94AYCDN X225 130
Ethernet 2 port 60
EtherNet/IP X232 130
POWERLINK E94AYCEP
POWERLINK CN E94AYCEC
X210/X250 140
EtherCAT® X245 130
PROFIBUS E94AYCPM X200 130 5 650
PROFINET E94AYCER X240 140
INTERBUS X205 180
Safety system (MSI)
SM0 E94AYAA 0 2 0
SM100 E94AYAB
X80
200 3 600
− digital output max. 700 5 x 10 % 350
SM301 E94AYAD
X80.2
350
− clock output 50
− safe digital output X80.1 500
Example values in italics
Result: current requirement of 24−V supply
Sum total [mA]: 8520
Sum total [A]: 8.5