Single−axis controllers
Device description
Devices in the range 145 ... 245 A (75 ... 130 kW)
3
85
EDS94SPP101 EN 10.2
Pos. Description
MXI1 Module receptacle for extension 1, e.g. communication
MXI2 Module receptacle for extension 2, e.g. communication
MMI Module receptacle for memory modules
MSI Module receptacle for safety equipment
X1 System bus (CAN), under the cover
X2 24−V supply / Statebus
X3 Analog inputs / analog outputs
X4 Digital outputs
X5 Digital inputs
X6 Diagnostics (with diagnostic adapter or keypad)
X7 Resolver
X8 Encoder
Lower cover
Retractable nameplate
Upper cover
EMC wire clamp
X100 Mains voltage
X104 DC−bus voltage/external brake resistor
X105 Motor
X106 Motor temperature monitoring (position depends on the device size)
X107 Control of motor holding brake
EMC shield clamp
Holes for transport and assembly guides
Bridge for operation in TT/TN or IT systems
The LED display enables fast indication of several operating states.
LED Labelling Colour Description
CAN−RUN green CAN bus ok
CAN−ERR red CAN bus error
DRIVE READY green Standard device is ready for operation
DRIVE ERROR red Error in the standard device or application−induced
24 V green 24 V supply voltage ok
SSP94LED01
USER yellow Message parameterised by the application
Pos. Symbol Description
Long discharge time: All power terminals carry hazardous electrical voltages
for a longer period of time after mains disconnection! Depending on the
device, this period of time may be up to 30 minutes.
High discharge current: Carry out fixed installation and PE connection
according to EN 61800−5−1!
Electrostatic sensitive devices: Before working on the device, the personnel
must be free of electrostatic charge!