EasyManua.ls Logo

Lenze L-force 9400

Lenze L-force 9400
646 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Single−axis controllers
Mechanical installation
Devices in the range 2 ... 24 A (0.37 ... 11 kW)
3
93
EDS94SPP101 EN 10.2
Installation steps
Proceed as follows for the installation:
1. Prepare M5 threaded holes on the mounting plate according to the mounting grid.
2. When using footprint filters: Screw installation backplane and footprint filter
together.
Use screw and washer assemblies M5 x 20 mm or hexagon socket screws
M5 x 20 mm with washers.
Tightening torque: 3.4 Nm (30 lb−in)
3. Screw the installation backplane or footprint filter with installation backplane onto
the mounting plate. Do not yet tighten the screws.
Use M5 screw and washer assemblies or M5 hexagon socket screws with washers.
The screw joint in the installation backplane may jut out no more than 7 mm.
4. Repeat steps 2 and 3 with further installation backplanes which are mounted side by
side.
5. Align all installation backplanes.
6. Screw all installation backplanes/footprint filters onto the mounting plate.
Tightening torque: 3.4 Nm (30 lb−in).

Table of Contents

Other manuals for Lenze L-force 9400

Related product manuals