3.6.5 Querying the device software version
You can query the device software version in the menu for configuring the ODSL 30. To do
this, select the following menu item in the Service Menu:
3.6.6 Referencing the device
The ODSL 30 is equipped with a referencing function for internally calibrating the sensor.
By carrying out the integrated reference measurement function before a measurement, the
sensor's accuracy can be improved.
A referencing operation is performed
when switching on the device (Power-On).
by means of a signal at the activation/referencing input (PIN 2).
by means of a command in remote control operation (ODSL 30/D… only).
Notice
In particular, the referencing function should be performed for changing environmen-
tal conditions.
While the referencing function is carried out (duration about 350ms), no measure-
ment can be taken.