Description ODSL 30
Leuze electronic ODSL 30 29
TNT 35/7-24V
3.5 Operation with fieldbus and Ethernet
Sensors ODSL 30/D232-30M-S12 with an RS 232 serial interface can be connected with
MA 2xxi modular interfacing units to the following fieldbus and Ethernet types:
•PROFIBUSDP –> MA 204i
• Ethernet TCP/IP –> MA 208i
• CANopen –> MA 235i
• EtherCAT –> MA 238i
•PROFINET-IO –> MA 248i
• DeviceNet –> MA 255i
• EtherNet/IP –> MA 258i
To do this, the modular interfacing unit is connected to the sensor via a connection cable.
To operate the distance sensors, rotary switch S4 of the modular interfacing unit must be set
to switch position B.
Further details can be found in the technical descriptions of the modular interfacing units.
Notice
The default settings of the ODSL 30/D232… serial interface have to be adjusted. For addi-
tional information on configuring the interface, refer to chapter 3.7.3.
Specifications for the serial interface
COM function: ASCII (see page 41)
Baud rate: 38400 baud (see page 41)