Description ODSL 30
Leuze electronic ODSL 30 41
TNT 35/7-24V
Serial COM Menu COM Function sel
ASCII Distance
COM Function sel
ASCII Distance
Serial transmission, output in
ASCII, 5 bytes, resolut. 1mm
X
COM Function sel
ASCII Dist. .1mm
Serial transmission, output in
ASCII, 6 bytes, resolut. 0.1mm
COM Function sel
Distance 14 bit
Serial transmission, 2 bytes,
15m meas. range, res. 1mm
COM Function sel
Distance 16 bit
Serial transmission, 3 bytes,
30m meas. range, res. 1mm
COM Function sel
Distance 20bit
Serial transmission, 4 bytes,
30m meas. range, res. 0.1mm
COM Function sel
Remote Control
Remote control activated,
RS 232 no bus operation
COM Function sel
switched OFF
Serial data transmission deac-
tivated
Node Address
Value: 000
Node Address
act Value: 000
Node address 0 14
0
Baudrate COM
Baudrate 9600
Baudrate COM
Baudrate 9600
Baud rate 9600 bit/s
X
Baudrate COM
Baudrate 19200
Baud rate 19200 bit/s
Baudrate COM
Baudrate 28800
Baud rate 28800 bit/s
Baudrate COM
Baudrate 38400
Baud rate 38400 bit/s
Baudrate COM
Baudrate 57600
Baud rate 57600 bit/s
Baudrate COM
Baudrate 115200
Baud rate 115200 bit/s
Baudrate COM
Baudrate 600
Baud rate 600 bit/s
Baudrate COM
Baudrate 1200
Baud rate 1200 bit/s
Baudrate COM
Baudrate 2400
Baud rate 2400 bit/s
Baudrate COM
Baudrate 4800
Baud rate 4800 bit/s
Stopbits COM
1
Stopbits COM
1
Number of stop bits: 1
X
Stopbits COM
2
Number of stop bits: 2
Return
Return to level 1
Service Menu Password Check
inactive
Password Check
inactive
Password for menu access not
active
X
Password Check
activated
Menu access password active,
password: 165 (n. changeable)
ODSL 30 Serial No
Val: 99999
Display of serial number, no
changes possible
SW V01.20 YYMMDD
Val: 31024
Display of software version, no
changes possible
Parameter YYMMDD
Val: 31024
Display of parameter version,
no changes possible
Interface-Type
RS 232 Interface
Display of the interface type,
no changes possible
Return
Return to level 1
Exit from Menu
Return to measurement mode
Level 1 Level 2 Level 3 Level 4 Explanation / Notes Default