Description ODSL 30
36 ODSL 30 Leuze electronic
3.7.2 Configuration / menu structure ODSL 30/24… (3 switching outputs)
Level 1 Level 2 Level 3 Level 4 Explanation / Notes Default
Applic. Param. Tmeas Bgnd Rem.
100ms 150 m 6-90 %
Tmeas Bgnd Rem.
100 ms 150 m 6-90 %
Measurement time / unique-
ness range / object reflectivity
X
Note
The functions under Applic. Param.
are not available until the
Advanced Menu is activated
(see chapter 3.8)
Tmeas Bgnd Rem.
80 ms 39 m 6-90 %
Measurement time / unique-
ness range / object reflectivity
Tmeas Bgnd Rem.
70 ms 9.8 m 6-90 %
Measurement time / unique-
ness range / object reflectivity
Tmeas Bgnd Rem.
50 ms 150 m 50-90 %
Measurement time / unique-
ness range / object reflectivity
Tmeas Bgnd Rem.
40 ms 39 m 50-90 %
Measurement time / unique-
ness range / object reflectivity
Tmeas Bgnd Rem.
30 ms 9.8 m 50-90 %
Measurement time / unique-
ness range / object reflectivity
Disp. Resolution
1mm
Disp. Resolution
1mm
Display resolution 1mm
X
Disp. Resolution
0.1mm
Display resolution 0.1mm
Offset/Preset Offset Direction
... positive
Offset Direction
... positive
Offset sign positive
X
Offset Direction
... negative
Offset sign negative
Offsetvalue [mm]
Value: 000000
Offsetvalue [mm]
act Val. 000000
Offset value, entry in mm
0
Presetvalue [mm]
Value: 000000
Presetvalue [mm]
act Val. 000000
Preset value, entry in mm
0
Preset Calculate
... inactive
Preset Calculate
... active
Trigger of the preset function
Return
Return to level 1
Input Menu Inp. teach Q1/Q2
Teach Out Q1/Q2
Inp. teach Q1/Q2
Teach Out Q1/Q2
Teach input is activated
X
Inp. teach Q1/Q2
Input disabled
Teach input is deactivated
Input activ/ref
Referencing
Input activ/ref
Referencing
Input is referencing input
X
Input activ/ref
Activation + Ref
Input is activation and refer-
encing input
Input activ/ref
Input disabled
Input activ is deactivated
Inp. teach Q3
Teach output Q3
Inp. teach Q3
Teach Output Q3
Teach input is activated
X
Inp. teach Q3
Input disabled
Teach input is deactivated
Input Polarity
active HIGH +24V
Input Polarity
active HIGH +24V
All inputs are active high
X
Input Polarity
active LOW 0 V
All inputs are active low
Return