Description ODSL 30
Leuze electronic ODSL 30 37
TNT 35/7-24V
Output Q Menu Q1 Function sel. Q1 Upper Sw. Pt.
Value: 001000
Q1 Upper Sw. Pt.
act Value: 001000
Upper switching point of out-
put Q1 in millimetres
1000
Q1 Lower Sw. Pt.
Value: 000199
Q1 Lower Sw. Pt.
act Value: 000199
Lower switching point of out-
put Q1 in millimetres
199
Q1 Hysteresis
Value: 000020
Q1 Hysteresis
act Value: 00020
Switching hysteresis of output
Q1 in millimeters
20
Q1 light/dark
light switching
Q1 light/dark
light switching
Q1 is active if an object is in
the switching range
X
Q1 light/dark
dark switching
Q1 is active if no object is
present in the switching range
Q1 Driver
PNP high active
Q1 Driver
PNP high active
Q1 is high-side output (PNP)
X
Q1 Driver
NPN low active
Q1 is low-side output (NPN)
Q1 Driver
PNP/NPN pushpull
Q1 is push-pull output
Return
Return to level 2
Q2 Function sel. Q2 Upper Sw. Pt.
Value: 001500
Q2 Upper Sw. Pt.
act Value: 001500
Upper switching point of out-
put Q2 in millimetres
1500
Q2 Lower Sw. Pt.
Value: 000199
Q2 Lower Sw. Pt.
act Value: 000199
Lower switching point of out-
put Q2 in millimetres
199
Q2 Hysteresis
Value: 000020
Q2 Hysteresis
act Value: 00020
Switching hysteresis of output
Q2 in millimetres
20
Q2 light/dark
light switching
Q2 light/dark
light switching
Q2 is active if an object is
present in the switching range
X
Q2 light/dark
dark switching
Q2 is active if no object is
present in the switching range
Q2 Driver
PNP high active
Q2 Driver
PNP high active
Q2 is high-side output (PNP)
X
Q2 Driver
NPN low active
Q2 is low-side output (NPN)
Q2 Driver
PNP/NPN pushpull
Q2 is push-pull output
Return
Return to level 2
Q3 Function sel. Q3 Upper Sw. Pt.
Value: 002000
Q3 Upper Sw. Pt.
act Value: 002000
Upper switching point of out-
put Q3 in millimetres
2000
Q3 Lower Sw. Pt.
Value: 000199
Q3 Lower Sw. Pt.
act Value: 000199
Lower switching point of out-
put Q3 in millimetres
199
Q3 Hysteresis
Value: 000020
Q3 Hysteresis
act Value: 00020
Switching hysteresis of output
Q3 in millimetres
20
Q3 light/dark
light switching
Q3 light/dark
light switching
Q3 is active if an object is
present in the switching range
X
Q3 light/dark
dark switching
Q3 is active if no object is
present in the switching range
Q3 Driver
PNP high active
Q3 Driver
PNP high active
Q3 is high-side output (PNP)
X
Q3 Driver
NPN low active
Q3 is low-side output (NPN)
Q3 Driver
PNP/NPN pushpull
Q3 is push-pull output
Return
Return to level 2
Return
Return to level 1
Level 1 Level 2 Level 3 Level 4 Explanation / Notes Default