Description ODSL 30
Leuze electronic ODSL 30 51
TNT 35/7-24V
Example:
With a uniqueness range of 9.8m, an object is located at a distance of 1m. The sensor
outputs a correct measurement value of 1m.
If the object is located at a distance of 10.8m or 20.6m or 30.4m etc. from the sensor, the
sensor outputs an incorrect measurement value of 1m, i.e. a correct measurement value is
only output for objects located within the uniqueness range.
Figure 3.11:ODSL 30 measurement values with a uniqueness range of 9.8m
3.8.3 Changing the Display Resolution
On delivery, the measurement resolution of the ODSL 30 (display) is 1mm. In the advanced
mode, the resolution of the display can be increased to 0.1mm by configuring with the
keypad and display:
Applic. Param. -> Disp. Resolution 0.1mm.
Notice!
This menu item refers only to the display. Changing this parameter has no direct effect
on the output at the serial or analogue interfaces.
If you would like to transmit measurement data with a resolution of 0.1mm using the
ODSL 30/D... with serial interface, this can be parameterized at a different location
(see chapter 3.4.3).
For the ODSL 30/V…, the measurement range is to be restricted by appropriately con-
figuring the analogue output.
The configuration of a resolution of 0.1mm is useful when performing measurements on
objects with high diffuse reflection and when the measurement data are processed further
(e.g. averaging).
0
0
10
20
10 20 30 40 50
60
Measurement value [m]
Distance [m]
Uniqueness range 9.8m