EasyManuals Logo

Lightware MMX4x2 Series User Manual

Lightware MMX4x2 Series
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
  

Event Manager Basics


These commands are detailed in the coming sections.
How to arrange an Event?
The following are necessary to have a successful event:
Condition
Action
Setting the Delay (optional)
Name the Event and set to Enabled
INFO: Setting the Event to Enabled as the last step is recommended.
Setting a Condition by Specifying a Direct Path
Command and Response
ç <loc>.Condition=<expression>
æ <loc>.Condition=<expression>
Parameters
The structure of the <expression> is: <node_path>.<property>=<value>.
Example 1
ç 
æ 
SignalPresent property changes to '1'.
Example 2
In some cases, the opposite is necessary: when the property does not equal with the value. If you need so,
the ConditionInverted property must be set to true:
ç 
æ 
ç 
æ 
ConnectedSource property does not equal with 'I1' (in other words: if other input
port is connected to O1 than I1).
Example 3
Sometimes, it is enough if the value of a property changes to anything. In this case, just put a ? to the end
of the property:
ç 
æ 
Setting a Condition by Linking Another Condition
Command and Response
ç <loc>.Condition=<event_nr>
æ <loc>.Condition=<event_nr>
Parameters
The <event_nr> means the number (location) of the linked event without letter 'E'.
Example
ç 
æ 
The Condition of the E2 Event is set to be the same as set at E1 Event.
Setting a Condition by Linking More Conditions
DIFFERENCE: 

is not enough. The practical experience has shown there is a need to examine more conditions (up to four)

Action is launched.
Command and Response
ç <loc>.Condition=<event_nr><event_nr><event_nr><event_nr>
æ <loc>.Condition=<event_nr><event_nr><event_nr><event_nr>
Parameters
The <event_nr> parameters mean the numbers (locations) of the linked Events without letter 'E'.
Example
ç 
æ 

Action of E4 will be launched.
TIPS AND TRICKS: 
Disabled.

Table of Contents

Other manuals for Lightware MMX4x2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware MMX4x2 Series and is the answer not in the manual?

Lightware MMX4x2 Series Specifications

General IconGeneral
BrandLightware
ModelMMX4x2 Series
CategoryMatrix Switcher
LanguageEnglish

Related product manuals