 MMX4x2 series – User's Manual 128

Infrared Message Sending
DIFFERENCE: 
Sending Pronto Hex Codes in Little-endian Format via IR Port
Command and Response
ç <hex_code>)
æ 
Parameters
Parameter Parameter description  
<hex_code> IR code in Pronto hex
format

hexadecimal format (0-9; A-F; a-f) without space
character in little-endian system.
INFO: This command can send exactly one pronto hex message. The header of the IR code contains the

For more details about the pronto hex codes, see the Messaging Options section.
Example
ç 




æ 
TIPS AND TRICKS: Download a code that belongs to your controlled device from a web database from the
Internet. The downloaded codes are mostly in little-endian format.
Sending Pronto Hex Codes in Big-endian Format via IR Port
Command and Response
ç <hex_code>)
æ 
Parameters
Parameter Parameter description  
<hex_code> IR code in Pronto hex
format

hexadecimal format (0-9; A-F; a-f) without space
character in big-endian system.
INFO: This command can send exactly one pronto hex message. The header of the IR code contains the

For more details about the pronto hex codes, see the Messaging Options section.
Example
ç 




æ 
IR code Learning with a terminal program
Step 1. Connect an IR detector to the IR input port.
Step 1. Connect to the MMX-4x2 series device with a terminal program.
Step 2. Push the desired button of the remote control to scan the raw IR code.
Step 3. Remove all the non-hexadecimal characters (e.g. spaces, h characters etc.) from the code.
big-endian format.

Table of Contents

Other manuals for Lightware MMX4x2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware MMX4x2 Series and is the answer not in the manual?

Lightware MMX4x2 Series Specifications

General IconGeneral
BrandLightware
ModelMMX4x2 Series
CategoryMatrix Switcher
LanguageEnglish

Related product manuals