USE AND MAINTENANCE MANUAL – DLC
NET
Series
LOGIC S.r.l. - M0145Db.docx
Mod. L0006A01 of 30/05/2016
appropriate corrections to ensure that anomalies fall and press
again.
If the checks are positive, the instrument gives consent to the dosage and
appropriately controls the valves according to the pre-action parameters
( ) and in flight amount ( ) set and the logic described in paragraph
6.1.2.
The product begins to flow and the weight indicator in the display begins to
increase.
On the instrument are activated two led:
o Flashing led / / / , indicating the automatic
component dosing
o Flashing led , which indicates that there is a recipe in
progress. This led will remain active until the recipe is not finished
It is possible pause the dosage by pressing the button. The display
will show . Press to resume.
When it reaches the setpoint minus the in-flight amount, the system waits
for the waiting time of the in-flight set amount and shows the written
, acquiring the data weight for the printer.
At this point, the led corresponding to the component dosing is steady on,
indicating that the filling process is ended. The led continues to blink
and the dosage is terminated.
To dose a new automatic component repeat the full procedure. To dose a
manual component, follow the instructions in section 6.4.3.
6.4.3 Dosing of manual
components ( )
In addition to the automatic components, it can be dose manual components that
are stored for printing.
To dose the manual component follow these steps:
Press the button to enter the ingredients selection menu ( ).
The display will show the written ( ), corresponding to the first
automatic ingredient.
Press at any time to cancel and return to the previous menu.
Use the button until the manual component words ( ).
The display shows the index of the next manual component to be dosed,
starting from 1.
Press to confirm and begin the dosing of the first manual
component.