Logs and Reports
207
Screen Contents
The screen displays a list of system faults under the following column headings:
DateDisplays the date that the error occurred.
TimeDisplays the time that the error occurred.
ProblemDisplays a brief description of the reason why the error has been generated. See
Example problems below.
Type This column displays the current status of the error:
o ActiveThe error is current and has not been cleared.
o EventThe error has been cleared.
o PassiveThe error has been listed for advice only
The log can hold up to 20 system fault records. If this number is exceeded and the log has not been
sent as a report, then the oldest record is deleted to provide space for a new record.
Example Problems
Some example system faults problems that may be displayed and suggested remedial actions are
listed below.
Problem: 5V out of spec - the 5V rail is less than 4.75V.
o Action: Contact your local Loma service centre for assistance.
Problem: +12V out of spec - the +12V rail is less than 11.40V.
o Action:Contact your local Loma service centre for assistance.
ProblemVerdict too late - a pack has arrived at the reject point before the detector has
sent a reject decision.
o Actions:
1. Increase the reject delay time.
2. If a product registration photo-eye is installed, reduce the pack length.
Problem: Verdict mismatch - the system has more reject verdicts than packs passed.
o
Action: Power machine off and on.