Chapter 1 Introduction
1-3
(d) Improved maintenance ability by types of comment backup.
(e) Built-in RTC function enabling convenient history and schedule management
(5) Optimized communication environment.
(a) With max. 2 channels of built-in COM (1 channel for E type (except load port)), communication is
available without any expanded of module.
(b) Supporting various protocols to improve the convenience (dedicated, Modbus, user-defined
communication)
(c) Communication module may be additionally increased by adding modules (up to 2 stages such as Cnet,
Enet and etc). (S(U) type main unit)
(d) Convenient network-diagnostic function through network & communication frame monitoring.
(e) Convenient networking to upper systems through Enet or Cnet. (S(U) type main unit)
(6) Applications expanded with a variety of I/O modules.
(a) 8, 16, 32 points modules provided (if relay output, 8/16 points module).
(b) Single input, single output and combined I/O modules supported.
(7) Applications expanded through analog-dedicated register design and full attachable mechanism.
(a) All analogue modules can be attachable on extension base. (S(U) type: up to 7 stages available)
(b) With analog dedicated register(U) and monitoring dedicated function, convenient use for I/O is
maximized (can designate operations using easy programming of U area and monitoring function)
(8) Integrated programming environment
(a) XG 5000: intensified program convenience, diverse monitoring, diagnosis and editing function
(b) XG - PD: COM/network parameters setting, frame monitoring, protocol analysis function
(9) Built-in high speed counter function
(a) Providing High-speed counter 1phase, 2phase and more additional functions.
(b) Providing parameter setting, diverse monitoring and diagnosis function using XG5000.
(c) Monitoring function in XG5000 can inspect without program, inspecting external wiring, data setting and
others.
(10) Built-in position control function (S(U) type TR output main unit)
(a) Supporting max 100Kpps 2 axes.
(b) Providing parameter setting, operation data collection, diverse monitoring and diagnosis by using
XG5000.
(c) Commissioning by monitoring of XG5000, without program, inspecting external wiring and operation data
setting.