Chapter 11 TR Output Option Board
11 - 8
(d) Emergency stop
It immediately stops if it meets emergency stop while performing start-related instructions (indirect start,
direct start, Home Return start, jog start).
Emergency stop generates Error 481.
Since it turns into Output prohibited status and un-defined origin status, once emergency stop is
executed, execute origin determination (Home return, Current position preset) again to run an
instruction that requires defined origin status
11.3.5 Manual operation
In general, manual operations refer to operation which doesnt use operation data. In output option board,
JOG operation is supported.
(1) JOG operation
Jog operation means positioning by jog operation stat contact point
Jog forward start
Jog backward start
Jog high speed/low
speed
XBO-
TN04A
X-axis
U9.1.8
U9.1.9
U9.1.A
Y-axis
U9.17.8
U9.17.9
U9.17.A
It is operated by jog speed set in positioning parameter.
It can be executed when origin is not determined.
Acceleration/deceleration process is controlled by the duration set in jog acceleration/deceleration time
among parameter settings of this software package.
If jog speed is set out of allowable range, it generates an error and operation is not available
Range
High speed jog
operation
1 100,000
(Unit: 1pps)
Low speed jog
operation
1 jog high speed
Remark
Make sure to follow the cautions
Bias speed Jog high speed Speed limit