In order to output the compared output signal, compared output enable flag set to ‘1’ after
compared output condition set.
Classification
Area per channel
Operation
Ch. 0 Ch. 1 Ch. 2 Ch. 3 Ch. 4 Ch. 5 Ch. 6 Ch. 7
Count enable
signal
K2600 K2700 K2800 K2900 K21800 K21900 K22000 K22100
0:disable, 1:
enable
Compared 0
enable signal
K2604 K2704 K2804 K2904 K21804 K21904 K22004 K22104
0: disable, 1:
enable
Compared 1
enable signal
K2607 K2707 K2807 K2907 K21807 K21907 K22007 K22107
0: disable, 1:
enable
▪ In order to make external output, the compared coincidence output signal (P20~P2F) must
be set. If Compared output contact is ‘Off’ at Special Module Parameter Setting of XG5000,
Compared coincidence output signal (internal device) is only output.
Classification
Area per channel
Operation
Ch. 0 Ch. 1 Ch. 2 Ch.4 Ch.5 Ch. 6 Ch.7
Compared coincidence
output signal 0
K2612 K2712 K2812 K2912 K21812 K22012 K22112
0: Compared output Off
1: Compared output On
Compared coincidence
output signal 1
K2613 K2713 K2813 K2913 K21813 K22013 K22113
0: Compared output Off
1: Compared output On
• Comp. output point (P40 ~ P4F) setting