Operating manual
XA1000 / XP200 / XP400
Question and Answer IconNeed help?

Do you have a question about the Lufft XA1000 and is the answer not in the manual?

Lufft XA1000 Specifications

General IconGeneral
Product TypeAll-in-one weather sensor
ManufacturerLufft
Resolution (Wind Speed)0.1 m/s
WeightApprox. 1.5 kg
Measurement PrincipleUltrasonic, capacitive, piezoresistive
Measuring Range (Temperature)-40 to +60 °C
Measuring Range (Rel. Humidity)0 to 100 %RH
Accuracy (Rel. Humidity)±2 %RH
Measuring Range (Air Pressure)300 to 1200 hPa
Accuracy (Air Pressure)±0.5 hPa
Measuring Range (Wind Direction)0 to 360 °
Accuracy (Wind Direction)±3 °
Accuracy (Wind Speed)±0.3 m/s or ±3 %
OutputRS485, SDI-12
InterfaceRS-485, SDI-12
Operating Temperature-40 to +60 °C

Summary

Device Information

Device Description

Explains the purpose, features, and functionality of the measuring meter.

Device Depiction

Illustrates and labels the physical components of the device.

Technical Specifications

Scope of Delivery and Usage Guidelines

Scope of Delivery

Details the items included with the multifunction measuring meter.

Intended Use

Defines the proper applications and climate diagnostics context for the meter.

Improper Use

Warns against inappropriate applications and unauthorized modifications.

Safety Precautions

Provides essential safety advice for handling and operating the device.

User Responsibilities and Risks

Personnel Qualifications

Specifies the required knowledge and skills for device operators.

Residual Risks

Highlights potential hazards such as electric current, danger, and caution alerts.

Transport and Storage

Transport

Describes how to safely transport the multifunction measuring meter and accessories.

Storage and Operation

Storage

Provides guidelines for storing the device when not in use.

Operation

Explains how to insert batteries and power the device on/off.

Screen Element Description

Language Settings

Measuring Modes

Air Pressure Measurement

Details the air pressure measurement screen and its functions.

Automatic Air Pressure Measurement

Explains automatic measurement for the integrated air pressure sensor.

Flowrate Measurement

Describes the flow rate measurement screen and its parameters.

Automatic Flowrate Measurement

Covers automatic measurement for flow rate, including duration settings.

Flowrate Measuring Range

Explains how to set measuring ranges for volumetric flow calculations.

Humidity Measurement

Details the humidity measurement screen and its options.

Automatic Humidity Measurement

Explains automatic measurement for humidity, including duration settings.

CO2 Sensor Measurement

Describes the CO2 sensor measurement screen and its values.

Measured Values Explanation

Archive Management

Archive Overview

Displays saved measuring projects and navigation options.

Archive Entry Details

Shows details of a selected archive entry and options to open or delete.

Archive Data Visualization

Presents measured values in charts and tables for selected archive entries.

Device Settings

Screen Language and Unit System

Configure screen language and select between metric/imperial units.

Display Brightness and Time Configuration

Adjust screen brightness and set the device's date and time.

Automatic Display Dimming and Switch-off

Set periods for automatic screen dimming and power-off.

Sound Alerts and Altitude Setting

Enable/disable sound signals and input altitude for calculations.

Measurement Standards and Calibration Function

Select measurement standards and activate/deactivate calibration.

Pressure Reference Value

Set a fixed reference pressure for specific calculations.

Calibration

Activating the Calibration Function

Enables the calibration feature within the device settings.

Calibrating Internal Air Pressure Sensor

Guides through the process of calibrating the integrated air pressure sensor.

Calibrating Humidity/Temperature Sensor 8120.TFF

Details calibration for the 8120.TFF sensor for humidity and temperature.

Calibrating Temperature/Humidity Probe SDI

Explains calibration for SDI probes for temperature and humidity.

Calibrating CO2 Sensor

Outlines the steps for calibrating the CO2 sensor.

Calibrating SDI Sensor Flow Speed/Temperature

Describes calibration for SDI sensors for flow speed and temperature.

Calibrating Humidity/Temperature Sensor 8130.TFF

Mentions specialized calibration for the 8130.TFF sensor.

PC Software Installation and Use

Installing the PC Software

Guides on downloading and installing the SmartGraph3 PC software.

Starting the PC Software

Explains how to launch the software and connect the measuring meter.

Errors and Faults

Troubleshooting Device Startup

Provides steps to resolve issues when the device fails to switch on.

Troubleshooting No Measured Values

Offers solutions for when the device is on but displays no readings.

Status and Error Codes

Lists device error codes and their corresponding meanings for diagnosis.

Maintenance and Cleaning

Maintenance and Care Intervals

Outlines the schedule for device maintenance tasks.

Pre-Maintenance Activities

Details steps to take before performing maintenance or repairs.

Visual Device Inspection

Describes how to inspect the device for dirt, damage, and proper connections.

Cleaning the Device

Provides instructions for cleaning the device using a soft cloth.

Digital Sensors and Accessories

Available Digital Sensors

Lists and describes the various digital sensors compatible with the device.

Optional Accessories

Lists optional accessories available for purchase to enhance device functionality.

Disposal and Compliance

Disposal Guidelines

Provides instructions for the proper disposal of electronic equipment and batteries.

Declaration of Conformity

States the device's compliance with relevant EU directives and standards.