r-net user guide
39 5940A R-net User Guide DCR1266
magicmobility.com.au
3.8 Brake lamp short
This occurs when the control system detects a short in the Brake Lamp Circuit.
Check the brake lamps, cables and connections to the control system.
If the trip is still present after the above checks have been made, then the ISM may be defective. Refer to
Section 5.
3.9 Lamp short
This occurs when the control system detects a short in either of the Lamp Circuits
7205: Left Lamp Short
7209: Right Lamp Short
Check the lamps, cables and connections to the control system.
If the trip is still present after the above checks have been made, then the ISM may be defective. Refer to
Section 5.
3.10 Indicator lamp short
This occurs when the control system detects a short in either of the Indicator Circuits
7206: Left Indicator Short
720A: Right Indicator Short
Check the indicators, cables and connections to the control system.
If the trip is still present after the above checks have been made, then the ISM may be defective. Refer to
Section 5.
3.11 Indicator lamp failed
This occurs when the control system detects a failure in either of the Indicator Circuits. This is most likely to
be an indicator bulb failure.
7207: Left Indicator Failed
7208: Right Indicator Failed
Check the indicator bulbs, cables and connections to the control system.
If the trip is still present after the above checks have been made, then the ISM may be defective. Refer to
Section 5.
3.12 Over-current
This occurs when the control system detects an excessive amount of current in an Actuator Channel.
This may be due to a faulty endstop switch, actuator motor, cables or connections.
Check the movement of the actuator is not obstructed.
Check the endstop switches (if fitted) are terminating the power to the actuator motor.
If the trip is still present after the above checks have been made, then the SM or ISM may be defective. Refer
to Section 5.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Magic Mobility R-NET CJSM2 and is the answer not in the manual?

Magic Mobility R-NET CJSM2 Specifications

R-Net 80

Power IconPower
supply voltage24 Vdc
operating voltage16 Vdc to 35 Vdc
peak voltage35 Vdc
Current IconCurrent
brake current200 µA min. 1 A max.
battery charging current12 Arms max.
maximum drive current80 A
Environmental Specifications IconEnvironmental Specifications
moisture resistanceIPX4
operating temperature-25°C to +50°C
storage temperature-40°C to +65°C

R-Net 90

Power IconPower
supply voltage24 Vdc
operating voltage16 Vdc to 35 Vdc
peak voltage35 Vdc
Current IconCurrent
brake current200 µA min. 1 A max.
battery charging current12 Arms max.
maximum drive current90 A
Environmental Specifications IconEnvironmental Specifications
moisture resistanceIPX4
operating temperature-25°C to +50°C
storage temperature-40°C to +65°C

R-Net 120

Power IconPower
supply voltage24 Vdc
operating voltage16 Vdc to 35 Vdc
peak voltage35 Vdc
Current IconCurrent
brake current200 µA min. 1 A max.
battery charging current12 Arms max.
maximum drive current120 A
Environmental Specifications IconEnvironmental Specifications
moisture resistanceIPX4
operating temperature-25°C to +50°C
storage temperature-40°C to +65°C