Quattro DC Quick Parameter Reference
10
Sub
menu
Parameter Units Range Default
Site
Setting
A4 Motor Side Power Convert A4 Submenu – See Motor Side Power Convert on page 55.
A4 ARM INDUCTANCE mH
0.01 – 327.67
10.00
A4 ARM RESISTANCE ohm
0.0001 – 2.9999
0.1000
A4 MOTOR FIELD RES ohm
0.0 – 3276.7
9.0
A4 MOTOR FIELD TC sec
0.000 – 32.767
0.607
A4 AUTO TUNE MOTOR none
Start Autotune?
-
A4 GAIN SELECTION none
manual
use saved par
use self-tune
MANUAL
A4 GAIN BANDWIDTH A rad/sec
100 – 2000
500
A4 GAIN BANDWIDTH F rad/sec
1 – 40
5
A4 SPD MODEFILT BW rad/sec
5 – 110
100
A4 PWM FREQUENCY kHz
2.5 – 16.0
6.0
A4 UV ALARM LEVEL %
80 – 99
90
A4 UV FAULT LEVEL %
50 – 99
80
A4 FLD CARRIER FRQ kHz
3 – 40
3
A5 Line Side Power converter A5 Submenu – See Line Side Power Converter on page 57.
A5 Id REG PROP GAIN none 0 – 9.99 0.30
A5 Id REG INTGRL GAIN none
0 – 999
10
A5 Iq REG PROP GAIN none
0.00 – 9.99
0.30
A5 Iq REG INTGRL GAIN none
0 – 999
40
A5 DC BUS REG P GAIN none
0.00 – 9.99
3.00
A5 DC BUS REG I GAIN none
0 – 999
40
A5 INPUT L-L VOLTS volts
150 – 480
200
A5 INITIAL L FREQ Hz
50 – 60
55
A5 DC BUS V BOOST volts
15 – 75
30
A5 SW BUS OV LEVEL volts
100 – 850
850
A5 BUS VREF SOURCE none
track line v
trk vin param
TRACK LINE V
A5 PLL FILTER FC Hz
20.0 – 150.0
40.0
A5 POLE FILTER kHz
0.1 – 3.0
2.2
A5 PRE CHGE THRESH none
1 – 60
28
A5 LS PWM FREQUENCY kHz
8.0 – 12.0
10.0