Appendix – Low Voltage Field Module
154
Appendix
Low Voltage Field Module
Magnetek offers two version of the Field Module for Quattro™ DC. This document
details the appropriate use of each module.
The Low Voltage Field Module is recommended for applications with:
o 380-480 VAC 3-phase input to drive or 200-240 VAC 3-phase input to drive
when Field Current is less than 20 Amps
o Lower peak to peak and ground voltage on field when using higher input
voltage
The Standard Field Module is recommended for applications with:
o 200-480 VAC 3-phase input to drive where insulation stress is not a factor
o Applications that exceed output voltage/current rating of Low Voltage Field
Module
1
Low Voltage Field Module Specifications
Input Power
Powered from the DC Bus
Output Power
1
20 Amps at 250 Volts
2
40 Amps at 125 Volts
2
Standards
CSA
Design Features
40kHz switching frequency
Low Voltage to ground on field
winding insulation
Jumper on Field Module Board to
determine ampere range (see page 155 for
more information)
Standard Field Module Specifications
Input Power
Powered from the DC Bus
Output Power
Up to 40 Amps
Standards
CSA
Design Features
Settable switching frequency, FLD
CARRIER FRQ (A4)
Optional Field Filter helps with
high voltage peak to peak on field
winding insulation