Quattro DC Interconnections
24
Interconnections
LED1
LED2
LED3
LED4
LED5
LED6
LED7
LED8
LED9
Corresponding LED
1
on A6 Board
QUATTRO SIGNAL
CONNECTIONS
A6
+24 VISO
LOGIC OUTPUTS
LOGIC INPUTS
LED10
LED11
LED12
LED13
LED14
LED15
LED16
Corresponding LED
on A6 Board
SS RELAYS
SSR1
SSR2
ANALOG
OUTPUTS
A01
A02
AC
RELAYS
ENCODER
1
Note: Input LEDs do not
take into account setting
of N.C. Inputs (C2)
SERIAL CONNECTION
ANALOG INPUTS
+/- 10 V
AIN1+
AIN1-
ACOM
AIN2+
AIN2-
/A
A
/B
B
/Z
Z
C
_
ISO
+5VISO
+12VISO
LI1
LI2
LI3
LI4
LI5
LI6
LI7
LI8
LI9
LIB
C
_
24VISO
C
_
24VISO
C
_
24VISO
+24 VISO
BB 1
BB
_
2
BASE
ENABLE
JUMPER
LED17
LED18
LED19
LED20
Corresponding LED
on A6 Board
Corresponding LED
on A6 Board
TB2
TB1
11
1
2
3
4
5
6
7
8
9
44
45
TB1
47
11
25
26
27
28
29
30
31
32
33
45
21
22
23
24
12
13
14
1
3
5
8
10
12
34
35
36
37
38
39
40
41
42
15
16
17
18
19
7
14
46
TB2
To / From
Encoder,
Use +5 or +12
volt Supply
Power As
Required.
+24VISO
+24VISO
LO1
LO2
LO3
LO4
LO5
LO6
LO7
LOC
C
_
24VISO
C
_
24VISO
Rela
1
Rela
2
10
43
6*
A
8JCC1-1
A
8JCC1-2
*Located on A8TB4
Contact
Cfirm
CTR PWR Sense
5*
A
8JCC1-4
To/ From
Encoder, Use
+5 or +12 Volt
supply power
Speed Command
A
8JCC1-3
To contactor
pickup Relay K on
A
8
Open collector
Outputs, 30VDC,
150mA max
Solid State relay
Outputs,
50V AC/DC
Max 150mA Max
A
nalog Outputs,
+/- 10 VDC,
+/- 4mA
Relays, 230 VAC
1A or 30VDC 2A
1
6
2
7
3
8
4
9
5
JC4
+5V
_
S
A
-RTS
A
+CTS
A
TXRX+
TXRX-
RX-
RX+
COM
_
SA
RS422
Customer
Serial Link
PreTorque Cmd or
Torque Command
Figure 1: Interconnection Diagram