© Martin Engineering GmbH 70 M3727UK-09/15
Part numbers
9.14 Air volume
Compressed air specifications:
min. 5 bar
max. 10 bar
The quality of the compressed air used must at least fulfill class 5 of
the DIN ISO 8573-1 standard. Otherwise, Martin Engineering
cannot guarantee flawless operation of the air cannon.
9.15 Field of usage of the air cannon tanks
Air cannon tank
size
[l]
Part numbers (sizes)
37864 (2") 37798 (4") 37853 (6")
12 x
25 x x
50 x x
100 x x
150 x x
200 x x
300 x x
Tab. 6: Overview of the air cannon tank sizes
Pressure
range
[bar]
Part numbers (sizes)
Temperature range
[°C]
37864 (2") 37798 (4") 37853 (6")
10 x x x -50/+150
12 x x x -30/+150
Tab. 7: Pressure range