AC power 7
AC
POWER
2
The Wizard’s operating voltage is printed on the serial number label that can be
found on the back of the Wizard. Verify that the operating voltage closely
matches the AC supply voltage before applying power. Contact your Martin
dealer if the operating voltage differs from the supply voltage by more than five
percent.
INSTALLING A PLUG ON THE MAINS
LEAD
The fixture’s mains lead may require a grounding-type cord cap that fits your
power distribution cable or outlet. Consult a qualified electrician if you have any
doubts about proper installation.
Warning! For protection from dangerous electric shock, the fixture
must be grounded (earthed). The AC mains supply shall have
overload and ground-fault protection.
Important! Verify that the feed cables are undamaged and rated for the
current requirements of all connected devices before use.
Following the cord cap manufacturer’s instructions, connect the yellow and green
wire to ground (earth), the brown wire to live, and the blue wire to neutral. The
table below shows some pin identification schemes.
Wire Pin Marking Screw color
brown live “L” yellow or brass
blue neutral “N” silver
yellow/green ground green