8 Wizard user manual
ADJUSTING VOLTAGE SETTINGS
EU Model
1 Disconnect the fixture from AC power.
2 If the lamp is hot, allow it to cool for 5 minutes and wear safety goggles to protect
your eyes.
3 Remove the 6 cover-access screws and lift of the fixture cover.
4 On the transformer, move the BROWN wire to the transformer terminal shown in
the table above for the local AC supply voltage. The terminals are indicated on a
label on the top of the transformer.
5 On the ballast, move the BROWN wire to the terminal listed for the voltage. The
terminals are indicated on the top of the ballast.
6 Replace the cover.
Local AC Supply Transformer Ballast
Freq. Voltage Setting Terminal Setting / Terminal
50 Hz 220 - 235 V 225 V 3 230 V
50 Hz 235 - 245 V 240 V 4 240 V
50 Hz 245 - 260 V 240 V 4 250 V
Transformer
Ballast
225 V
240 V
230 V
240 V
250 V
0 V