EasyManua.ls Logo

Martin Wizard - Data Connection; Recommended Cable; Connections

Martin Wizard
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Data connection 13
D
ATA
CONNECTION
4
This section describes how to connect fixtures to each other, or to a controller.
RECOMMENDED CABLE
A reliable data connection begins with the right cable. Standard microphone
cable cannot transmit DMX data reliably over long runs. For best results, use
cable specifically designed for RS-485 applications. Your Martin dealer can
supply high quality cable in various lengths.
CONNECTIONS
The Wizard’s XLR data sockets are wired with pin 1 to ground, pin 2 to signal -
(cold), and pin 3 to signal + (hot). This is compatible with the standard for DMX
devices.
One or more adaptor cables may be required to connect the Wizard to the
controller and/or other lights because many devices have 5-pin connectors and
others may have reversed signal polarity, that is, pin 2 hot and pin 3 cold.
Phase-Reversing
Adaptor
Male Female
1
2
3
1
2
3
3-pin to 3-pin
P/N 11820006
Adaptor
Male Female
1
2
3
4
5
1
2
3
5-pin to 3-pin
P/N 11820005
Adaptor
Male Female
1
2
3
1
2
3
4
5
3-pin to 5-pin
P/N 11820004

Related product manuals