EasyManua.ls Logo

Masimo Radical User Manual

Masimo Radical
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Signal Extraction Pulse Oximeter
OPERATOR’S MANUAL

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Masimo Radical and is the answer not in the manual?

Masimo Radical Specifications

General IconGeneral
TypePulse Oximeter
BrandMasimo
SpO2 Measurement Range0-100%
Perfusion Index (PI) Range0.02-20%
Measurement ParametersSpO2, Pulse Rate, Perfusion Index (PI), Pleth Variability Index (PVI)
Power SourceAC power or internal battery
Battery TypeLithium-ion
Data StorageUSB
ConnectivityUSB
Operating ConditionsTemperature: 5°C to 40°C, Humidity: 15-95% non-condensing
DimensionsVaries by model
WeightVaries by model
Storage ConditionsHumidity: 15-95% non-condensing

Summary

System Description

Radical Handheld Front Panel

Details the controls, display, and indicators of the handheld unit's front.

Radical Standalone Front Panel

Details the controls, display, and indicators of the standalone unit's front.

Setup

Radical Power Requirements

Specifies AC power needs, voltage, frequency, and safe connection practices.

SatShare Setup

Describes how to connect the Radical to a multiparameter monitor via SatShare.

Operation

Successful SpO2 Monitoring

Provides guidance for optimal SpO2 and pulse rate measurement.

Signal IQ and Low Perfusion

Explains Signal IQ for quality assessment and handling low perfusion conditions.

Alarms and Their Management

Explains alarm settings, silencing, and volume adjustments.

Alarms and Messages

Alarm Operation and Messages

Describes how alarms function and lists common alarm messages.

System Messages and Causes

Lists system messages, their possible causes, and recommended actions.

Troubleshooting

Troubleshooting Common Problems

Provides solutions for common operational issues and system failures.

Specifications

Performance Specifications

Details measurement ranges, accuracy, and resolution for SpO2 and pulse rate.

Sensors and Patient Cables

Masimo LNOP Sensors

Covers the use, selection, and cautions for Masimo LNOP sensors.

Masimo SET Patient Cables

Covers the use, cleaning, and cautions for Masimo SET patient cables.

Service and Maintenance

Battery Operation and Maintenance

Details battery charging, estimated run times, and care.

Performance Verification Tests

Outlines procedures for testing device performance after repair or during maintenance.