Operator's Manual
Root
®
with noninvasive blood pressure and
temperature

Table of Contents

Other manuals for Masimo Root

Questions and Answers

  • R
    ryansparksSep 10, 2025
    Why is my Masimo Measuring Instruments not displaying data from Radical-7, Radius-7, or MOC-9 modules?
    • G
      Gary HardySep 10, 2025
      If your Masimo Root isn't displaying data from Radical-7, Radius-7, or MOC-9 modules, it may be due to a connection error. Check that all connections are secure and properly plugged in, and that the cable is not defective. For Radius-7, ensure that the device is paired with Root via Bluetooth.
  • B
    Brandon SalinasAug 22, 2025
    Why is my Masimo Root Medical Equipment battery not charging?
    • S
      Stacey PerezAug 22, 2025
      If the battery on your Masimo Medical Equipment does not charge, the AC power cable may be disconnected. Unplug and replug the AC power cable to ensure a proper connection.
  • K
    Kyle GallegosAug 25, 2025
    Why won't my Masimo Medical Equipment Root turn on?
    • J
      John MatthewsAug 25, 2025
      Your Masimo Root device may not be turning on because the power button wasn't pressed long enough. Try pressing and holding the power button for two seconds. Also, the battery might be depleted; connect the Root to AC power to charge it. Finally, one of the fuses might not be working correctly; in this case, replace the fuse.
  • T
    Tiffany CarrAug 26, 2025
    What to do if Masimo Medical Equipment Root turns on but the main screen is dim?
    • L
      Lindsey BryantAug 27, 2025
      If your Masimo Medical Equipment Root turns on but the main screen is dim or blank, the brightness setting may be incorrect. Adjust the brightness setting to resolve this issue.
  • A
    Anna JacksonAug 27, 2025
    Why is my Masimo Root Medical Equipment not displaying data from modules?
    • S
      Stacey RuizAug 28, 2025
      If your Masimo Medical Equipment is not displaying data from Radical-7, Radius-7, or MOC-9 modules, a connection error may be the cause. Ensure that all connections are securely in place and properly plugged in, and verify that the cable is not defective. If using Radius-7, ensure that the device is paired with Root via Bluetooth.
  • S
    scottkevinAug 29, 2025
    What to do if Masimo Medical Equipment Root has a continuous speaker tone?
    • P
      philip63Aug 29, 2025
      If your Masimo Medical Equipment Root has a continuous speaker tone, press the Power Button for eight seconds to silence the alarm. If the alarm continues to sound, power off Root.
  • K
    Kelly HowellSep 18, 2025
    What to do if Masimo Measuring Instruments Root has a continuous speaker tone?
    • E
      emanningSep 18, 2025
      To silence the alarm on your Masimo Root, press the Power Button for eight (8) seconds. If alarm continues to sound, Power Off Root.
  • E
    edanielsSep 12, 2025
    What to do if the Power Button does not respond when pressed on Masimo Measuring Instruments?
    • R
      Raymond GarciaSep 12, 2025
      If the power button on your Masimo Root isn't responding, try pressing and holding it for two seconds to power on from a turned-off or sleep state. To power off from an on or sleep state, press and hold the power button for eight seconds.
  • U
    ugilesSep 8, 2025
    What to do if Masimo Measuring Instruments Root does not turn on?
    • T
      Thomas WilliamsSep 8, 2025
      If your Masimo Root device doesn't turn on, make sure you press the power button for at least two seconds. Also, the battery might be depleted, so connect Root to AC power to charge it. If the issue persists, one of the fuses might not be working correctly and should be replaced.
  • L
    leeandreaSep 5, 2025
    Why is my Masimo Medical Equipment Root not displaying data from Radical-7, Radius-7, or MOC-9 modules?
    • S
      Sally JonesSep 5, 2025
      If your Masimo Root isn't displaying data from modules, there may be a connection error. Ensure all connections are secure and properly plugged in, and that the cable is not defective. For Radius-7, make sure the device is paired with Root via Bluetooth.

Summary

About This Manual

Product Description, Intended Use, and Indications for Use

Details the Masimo Root monitoring system's features, intended use, and indications for medical monitoring.

Safety Information, Warnings, and Cautions

Safety Warnings and Cautions

Covers essential safety warnings and precautions for operating the Masimo Root device.

Performance Warnings and Cautions

Highlights warnings related to device performance, alarms, and network connectivity.

Cleaning and Service Warnings and Cautions

Provides safety guidelines for cleaning, maintenance, and servicing the Root device.

Compliance Warnings and Cautions

Details warnings related to regulatory compliance, disposal, and environmental operation.

Chapter 1: Description

Features

Describes the key features and components of the Masimo Root device.

Chapter 2: Setting Up

Unpacking and Inspection

Instructions for safely unpacking and inspecting the Root device upon receipt.

Setup Guidelines and Basic Operations

Covers essential setup guidelines, powering on, and initial battery charging.

Connecting Modules and Peripherals

Guides on connecting various modules like Radical-7, Radius-7, MOC-9, and peripherals.

Chapter 3: Operation

About the Main Screen

Overview of the main screen layout and its primary components.

About the Status Bar

Explanation of icons and indicators present in the status bar.

About the Action Bar

Details the functions and options available through the action bar.

Using the Touchscreen Interface

Describes various touch gestures and controls for interacting with the device.

Menu Navigation

Explains how to navigate through menus and confirm or cancel settings.

Understanding Windows

Details how to view and customize data windows for connected devices.

Accessing Main Menu Options

Guide to accessing and navigating the main menu options on the device.

Chapter 4: Temperature Measurement

Operation - Temperature

Provides instructions for operating the temperature measurement function.

Temperature Probes

Details the types of temperature probes available and their usage.

Chapter 5: NIBP Measurement

Patient Measurement Mode and Setup

Covers selecting patient categories, cuff size, and conditions for NIBP measurement.

Operation - NIBP

Instructions for performing NIBP measurements in various modes.

Chapter 7: Electronic Medical Record (EMR) Push

Determining EMR Push Status

Explains how to check if the EMR Push feature is active.

Manually Entering and Sending Patient Data

Guides on manually entering patient data and sending it to the EMR.

Chapter 8: Radical-7

Chapter 9: Radius-7

Chapter 10: MOC-9

Using MOC-9 Ports

Instructions for connecting MOC-9 modules to the Root device.

Chapter 11: Iris

Iris Connectivity and Status

Details Iris connectivity, ports, icons, and screen status indicators.

Chapter 12: Bluetooth Devices

Connecting Devices via Bluetooth

Step-by-step guide to connecting external devices to Root via Bluetooth.

Chapter 13: Messages

Chapter 14: Troubleshooting

Troubleshooting Modules

Troubleshooting steps for Radical-7, Radius-7, and MOC-9 modules.

Troubleshooting Root

Common issues and their solutions for the Root device.

Chapter 15: Specifications

Measurement Accuracy

Technical specifications for NIBP and Temperature measurement accuracy.

Alarms, Nurse Call, and Connectors

Details alarm types, nurse call specifications, and device connectors.

Display Ranges and Pressurization

Specifies display ranges for parameters and NIBP pressurization limits.

Electrical, Environmental, and Wireless Specs

Covers electrical requirements, environmental operating conditions, and wireless specifications.

Communication Protocols and Security

Details Wi-Fi, Bluetooth communication, and security/authentication methods.

Regulatory Compliance and Standards

Lists radio compliance, certifications, and electromagnetic compatibility standards.

Chapter 16: Service and Maintenance

Cleaning and Fuse Replacement

Instructions for cleaning the device and replacing internal fuses.

NIBP Module Testing and Calibration

Procedures for NIBP module calibration, leak tests, and overpressure tests.

Battery and Repair Procedures

Covers battery testing, repair policies, return procedures, and technical services.

Appendix: Concepts of Alarm Response Delay

Concepts of Alarm Response Delay

Explains the components and concepts of alarm response delay.

Masimo Root Specifications

General IconGeneral
CategoryMedical Equipment
Display10.1 inch touchscreen
ConnectivityWiFi, Bluetooth
Power SupplyAC power
Dimensions26.8 cm x 22.4 cm x 5.1 cm
PortsUSB, Ethernet
Supported ParametersSpO2, Pulse Rate
CompatibilityMasimo sensors
ModelRoot