EasyManua.ls Logo

Mastervolt MASS COMBI 12/2500-100

Mastervolt MASS COMBI 12/2500-100
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TECHNICAL DATA
EN / Mass Combi 12/2500-100; 24/2500-60; 48/2500-35; 48/5000-70 / May 2010 43
10.2 SPECIFICATIONS CHARGER
Model Mass Combi 12/2500-100 24/2500-60 48/2500-35 48/5000-70
AC input
Nominal voltage / frequency 230V 50/60Hz 230V 50/60Hz 230V 50/60Hz 230V 50/60Hz
Input voltage, 100 % output 207 … 265VAC 207 … 265VAC 207 … 265VAC 207 … 265VAC
Input voltage, reduced output power 180 … 207VAC 180 … 207VAC 180 … 207VAC 180 … 207VAC
Absolute maximum voltage range 0 … 265VAC 0 … 265VAC 0 … 265VAC 0 … 265VAC
Input frequency range 45 … 65Hz 45 … 65Hz 45 … 65Hz 45 … 65Hz
Absolute maximum frequency range 0 … 70Hz 0 … 70Hz 0 … 70Hz 0 … 70Hz
Nominal input current (@230V) 7.2 A 8.5 A 8.5 A 17 A
Input phase Single phase, 3 wire system Single phase, 3 wire system
Insulation class Class I Class I Class I Class I
Power factor > 0,98 > 0,98 > 0,98 > 0,98
Harmonic distortion THD 3% 3% 3% 3%
Efficiency at full output > 85% > 85% > 85% > 85%
No–load power consumption < 15W < 15W < 15W < 30W
Model Mass Combi 12/2500-100 24/2500-60 48/2500-35 48/5000-70
DC output
Nominal output voltage
12VDC
(0…15.5VDC)*
24VDC
(0…31.0VDC)*
48VDC
(0…62VDC)*
48VDC
(0…62VDC)*
Max. total output current
100A @ U
14,25VDC
60A @ U
28,5VDC
35A @
U 57VDC
70A @
U 57VDC
Second charge output: 5A 5A No No
Charge characteristic Three stage, fully automatic, IUoUo, Equalize
Equalize mode, output current: 10A 6A 5A 12A
Equalize mode, max. output voltage: 15,5VDC 31.0VDC 62VDC 31.0VDC
Equalize mode, maximum duration: 6 hrs. 6 hrs. 6 hrs. 6 hrs.
Model Mass Combi 12/2500-100 24/2500-60 48/2500-35 48/5000-70
Factory settings
Return Amps* 6% of maximum output current 6% of maximum output current
Max bulk, abs timer* 6 hours 6 hours 6 hours 6 hours
Return amps timer* 15 minutes 15 minutes 15 minutes 15 minutes
Return to bulk delay time* 30 seconds 30 seconds 30 seconds 30 seconds
Battery temperature compensation –30mV per °C / –17mV per °F –60mV per °C / –33mV per °F
Battery voltage sense automatic voltage compensation
Protections Short circuit (current is reduced to 25% of I-max)
Battery types Acid Gel AGM/ Spiral Traction **
Bulk 14.40V / 28.80V / 57,6V 14.40V / 28.8V / 57,6V 14.60V / 29.20V / 58,4
Charge voltage Absorption* 14.25V / 28,50V / 57V 14.25V / 28.50V / 57V 14.45V / 28.90V / 57,8
Charge voltage Float* 13.25V / 26.50V / 53V 13.80V / 27.20V / 54,4 13.25V / 26.50V / 53
Forced to Float 13.25V / 26.50V / 53V 13.80V / 27.20V / 54,4 13.25V / 26.50V / 53
* adjustable by means of MasterAdjust software.
** traction max ABS/BULK time + 120min.

Table of Contents