EasyManuals Logo

Matrix Vision User Manual

Matrix Vision
235 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
Matrix
34
Vision System Manual
Example 2:
Program Allowed List and Denied List for following constraints:
1. Allow all numbers except ‘ISD’.
2. Only local calls should be allowed in dynamic lock condition.
3. Disconnect all calls starting with ‘0’ after 180 seconds except calls starting with ‘022’.
Solution:
First examine the default lists.
1. This condition can be fulfilled using default denied list 5.
2. This condition can also be fulfilled using default denied list 1.
3. In this case default denied list 4 could be used (since it contains 0). However an allowed list should be
programmed to program 022 in allowed list.
Use following command to program 022 in allowed list 4.
1202-1-4-00-022-#*
However, 022 can be programmed in any of the allowed lists.
Important Point:
To know programming details, please refer “
Configuration Reports”.
Relevant Topics:
1. Toll Control 184
2. Dynamic Lock 107
3. Call Duration Control 48