9. Use the ARROW keys to modify the oscillation
speed, as displayed on line 4. The left ARROW
key decreases the time per direction change
(increases speed). The right ARROW key
increases the time per direction change
(decreases speed). If an ARROW key is held
down, the speed of the change increases. If
both ARROW keys are pressed simultaniously,
the fastest speed is selected, which is 0.01
seconds. Press the ENTER key to store the
changes, or if no key is pressed within 20
seconds, the changes will be stored
automatically. The counter at the end of Line 3
increments on each direction reversal.
10. Pressing the MANUAL key while the oscillator
is running, will pause the oscillation. PAUSED
will be displayed on line 2. The unit will remain
paused until another command is issued.
12. Pressing the MANUAL key a second time will
exit the oscillator mode, and return to the
Operator Level.