11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
52
STEP 10 - REMOVE LOCKING ANGLE AND CHECK FOR
INTERFERENCE - Continued
3. Remove fl oor jack and
hoist supporting Liftgate
(FIG. 52-1).
FLOOR JACK
FIG. 52-1
LOWERING PLATFORM
FIG. 52-2
4. Lower platform to the ground (FIG. 52-2).
Look for any interference between liftgate
and vehicle as platform is lowered. Then,
raise the platform (FIG. 52-3). Look for any
interference between liftgate and vehicle as
platform is raised.
RAISING PLATFORM
FIG. 52-3
5. Lower platform to the ground (FIG. 52-4).
REMOVING INSTALLATION BRACKETS
FIG. 52-4
6. Unbolt and remove the 2 installa-
tion brackets from extension plate
(FIG. 52-4).
EXTENSION
PLATE
BOLT (2 PLACES)
INSTALLATION
BRACKET (2 PLACES)
NUT