Reciprocating Compressor M Series
5-1
5 Maintenance
5.1 Safety Precautions for Maintenance
z Be careful so as not to receive an electrical shock when turning on/off the power of each unit.
z Before performing maintenance, turn off the motor (main power) and control power, and then perform
lockout and tagout.
z Before performing maintenance, turn off the power of instruments such as a heater. Be careful that the
power does not turn on during maintenance.
z Check that pressure inside the compressors is at atmospheric pressure before disassembling the machine
for inspection.
z After temperature of the castings (such as head cover) is decreased to normal, perform the work.
z When handling the heavy objects, take sufficient care, and handle them with at least one other person
Replace the parts with the
genuine parts.
z When disassembling/assembling the compressor, always use the correct tools.
z All work should be performed only by qualified personnel.