68
P01.29
Estimated
temperature
of motor
Estimated
temperature
of motor
0~200℃ 1℃
0 × √ *
P01.30~
P01.31
Reserved
P01.32
Torque
reference
Torque
reference
-300.0%~300.0% (relative motor rated
torque)
0.1% 0.0%
× √ *
P01.33~
P01.41
Reserved
P01.42
Pulse
frequency
of terminal
X6
Pulse
frequency of
terminal X6
0.0~100.0KHz 0.1 0.0 × √ *
Group P02: Basic parameters
P02.00 Reserved
P02.01
Motor
selection
Motor
selection
0: Motor 1
1: Motor 2
1 0 × √ ×
P02.02
Running
command
channel
selection
Command
channel
selection
0: Keyboard control
1: Terminal control
2: Communication control
3: Bus control
1 0 √ √ ○
P02.03
Running
direction
setting
Running
direction
setting
0: Forward running;
1: Reverse running
1 0 √ √ ○
P02.04
Main
reference
frequency
source
selection
Main
reference
source
selection
0: Digital reference 1: Keyboard ∧∨
reference
1: Digital reference 2: Terminal UP/DN
reference
2: Serial port communication reference
3: AI analog reference
4: Terminal PULSE reference
5: Internal PLC running
6: Process closed loop PID
7: Multi-speed
8: Bus reference
1 0 √ √ ○
P02.05
Digital
setting of
main
reference
frequency
Main
reference
frequency
setting
P02.17~P02.16 0.01Hz 50.00 √ √ ○
P02.06
Main &
auxiliary
reference
digital
frequency
control
Main &
auxiliary
reference
frequency
control
Unit place of LED: Main digital
frequency saving control
0: Save when power down
1: Do not save when power down
Tens place of LED: Main digital
1 0000 × √ ○