75
function
upon power
fault
P08.17
Waiting
time for
restart upon
power fault
Restart
waiting time
0.0~3600.0s 0.1s 0.0s ×
P08.18
Anti-reverse
selection
Anti-reverse
selection
0: Reverse operation is allowed
1: Reverse operation is prohibited (run
at zero frequency upon reverse
running command)
1 0 × ×
P08.19
FWD/REV
dead- time
FWD/REV
dead- time
0.00~360.00s 0.01s 0.00s ×
P08.20
FWD/REV
switching
mode
FWD/REV
switching
mode
0: Switch once over the zero frequency
1: Switch once over the startup
frequency
1 0 × ×
P08.21
Use ratio of
dynamic
braking
Use ratio of
braking
0.0~100.0 (0: Disabled) 0.1 00.0
×
P08.22
Braking
startup
voltage
Braking
startup
voltage
700~780 1 750 ×
P08.23
Deceleratio
n time for
emergency
stop
Deceleration
time for
emergency
stop
0.00~100.00s (0: Automatic
high-speed deceleration)
0.01s 0.00s ×
Group P09: Digital input/output parameters
P09.00~
P09.05
Function
selection of
input
terminals
X1~X6
X1 ~ X6
Terminal
functions
0: No function
1: Forward running (FWD)
2: Reverse running (REV)
3: External jog forward running control
input
4: External jog reverse running control
input
5: Three-wire operation control
6: Multi-stage reference terminal 1
7: Multi-stage reference terminal 2
8: Multi-stage reference terminal 3
9: Multi-stage reference terminal 4
10: Acceleration/deceleration time
terminal 1
11: Acceleration/deceleration time
terminal 2
12: Main reference frequency pulse
input (valid only for X6)
13: Auxiliary reference frequency pulse
input (valid only for X6)
14: Frequency increase command
1
1
2
0
0
0
0
×