78
filtering time filtering time
P09.15
Input
terminal
enabled
status
setting
Input
terminal
enabled
status
Binary setting:
0: Normal logical, enabled upon
connection
1: Inverted logical, enabled upon
disconnection
Unit place of LED:
BIT0~BIT3: X1~X4
Tens place of LED:
BIT0~BIT1: X5~X6
1 00 ×
P09.16
Virtual input
terminal
setting
Virtual input
terminal
setting
Binary setting:
0: Disabled
1: Enabled
Unit place of LED:
BIT0~BIT3: X1~X4
Tens place of LED:
BIT0~BIT1: X5~X6
1 00 ×
P09.17
Output
selection of
Multi-functio
nal output
terminal Y1
Output
selection of
Multi-functio
nal output
terminal Y1
0: Open collector output terminal Y1
1: DO terminal output
1 0
×
P09.18
Open
collector
output
terminal Y1
Y1 function
selection
0: Drive in running state signal (RUN)
1: Frequency arrival signal (FAR)
2: Speed non-zero detection signal
3: Frequency level detection signal
(FDT1)
4: Frequency level detection signal
(FDT2)
5: Overload detection signal (OL)
6: Lockout for under-voltage (LU)
7: External fault stop (EXT)
8: Frequency upper limit (FHL)
1 0 ×
P09.19
Open
collector
output
terminal Y2
Y2 function
selection
1 1 ×