79
P09.20 Relay RO1
output
function
selection
RO1 function
selection
9: Frequency lower limit (FLL)
10: Drive running at zero-speed
11: Simple PLC stage running
completion indication
12: PLC cycle completion indication
13~14:Reserved
15: Drive ready for running (RDY)
16: Drive fault
17: Host device switch signal
18~33: Reserved
34: Drive FWD/REV indication terminal
35: Motor 1 and 2 indication terminal
36: Bus card ON/OFF signal
37~42: Reserved
43: PID feedback loss
44: PID feedback exceeding limit
Only the following function No. will be
shown in the shortcut menu: 0, 1, 3, 4,
5, 6, 7, 8, 9, 15, 16
1 15 ×
P09.21 Reserved
P09.22
Output
terminal
enabled
status
setting
Output
terminal
enabled
status
Binary setting:
0: Enabled upon connection
1: Enabled upon disconnection
Unit place of LED:
BIT0~BIT2:Y1Y2RO1
1 0 ×
P09.23
Relay RO1
output
delay
RO1 output
delay
0.1~10.0s 0.1s 0.1s ×
P09.24
Frequency
arrival
(FAR)
detection
width
Frequency
arrival
detection
width
0.00~3000.00Hz 0.01Hz 2.50Hz ×
P09.25
FDT 1 level
upper limit
FDT 1 level
upper limit
P09.26~ P02.16 0.01Hz
50.00H
z
×
P09.26
FDT 1 level
lower limit
FDT 1 level
lower limit
0.00~ P09.25 0.01Hz
49.00H
z
×
P09.27
FDT 2 level
upper limit
FDT 2 level
upper limit
P09.28~ P02.16 0.01Hz
25.00H
z
×
P09.28
FDT 2 level
lower limit
FDT 2 level
lower limit
0.00~ P09.27 0.01Hz
24.00H
z
×
P09.29
DO terminal
output
Digital output
0: No function
1: Output frequency
2: Set frequency (0~Maximum output
frequency)
3: Output current I
ei
(0~2 * I
ei
)
1 0

Table of Contents