4. Release the power button.
Recommended Operating Temperature Ranges for the Avator
7.5e Outboard
The Avator 7.5e outboard and battery were designed to operate in ambient air
temperature ranges above 0 °C (32 °F) and below 45 °C (113 °F).
Operating above the recommended ambient air temperature limit could cause
the motor or battery to overheat.
The following conditions will occur if high temperature limits are exceeded
during operation:
1. An initial over‑temperature warning fault will occur when the battery core
temperature exceeds 53 °C (127 °F). Power output will be reduced and a
non‑critical horn will sound once every key switch cycle until the battery
cools down.
2. If the battery temperature exceeds 60 °C (140 °F), the battery will shut
down and the display and motor will be rendered non‑functional until the
battery temperature is reduced. Operating below the lower limit of the
recommended ambient air temperature range may reduce the available
power and operating ranges.
Operating in Saltwater or Polluted Water
If the boat is kept in the water, always tilt the outboard so the outboard lower
motor unit is completely out of the water when not in use.
Wash the outboard exterior with fresh water after each use. Each month, spray
Mercury Precision or Quicksilver Corrosion Guard on external metal surfaces.
Do not spray on corrosion control anodes as this will reduce the effectiveness
of the anodes.
OPERATION
98 eng