OilLevel_Critically_Low
Fault Type: Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Nonsticky Caution 100% 713‑21 Yes 2
Explanation
The engine oil level appears to be low; the PCM received a signal from the oil level sensor that is lower than the specified
threshold.
Possible Causes
Engine oil level low
Wiring problem
Defective sensor
Summary of Fault Correction Possibilities
Add engine oil.
Inspect the wiring to the sensor, and repair as necessary.
Replace the sensor.
OilLevel_RangeHigh
Fault Type:
Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Nonsticky Caution 100% 711‑24 Yes 2
Explanation
The engine oil level sensor does not appear to be working properly; the PCM received a signal that is above the valid limit.
Possible Causes
Wiring problem
Defective sensor
Summary of Fault Correction Possibilities
Inspect the wiring to the sensor, and repair as necessary.
Replace the sensor.
OilLevel_Sensor_Faulted
Fault Type:
Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Nonsticky Caution 100% 711‑6 Yes 2
Explanation
The engine oil level sensor does not appear to be working properly.
Possible Causes
Wiring problem
Defective sensor
Summary of Fault Correction Possibilities
Inspect the wiring to the sensor, and repair as necessary.
Replace the sensor.