Summary of Fault Correction Possibilities
Inspect the wiring to the sensor, repair as necessary.
Replace the sensor.
StbdECT_RangeLow
Fault Type: Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Nonsticky Caution 100% 521‑25 Yes 2
Explanation
The engine coolant temperature (ECT) sensor does not appear to be working properly; the PCM received a signal that is below
the valid limit.
Possible Causes
Wiring problem
Defective sensor
Summary of Fault Correction Possibilities
Inspect the wiring to the sensor, repair as necessary.
Replace the sensor.
STRT_OutputFault
Fault Type:
Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Nonsticky Critical 100% 3171‑16 Yes 3
Explanation
The starting system does not appear to be working properly; the PCM detected a problem when trying to send a signal to the
start relay. The engine may not start.
Possible Causes
Wiring problem
Start relay failed
Starter failed
Summary of Fault Correction Possibilities
Check the wiring to the relay and to the starter, repair as necessary.
Replace the start relay.
Replace the starter.
SysVolt_FaultBlocker
Fault Type:
Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Nonsticky Critical 100% 4602‑23 Yes 3
Explanation
Battery voltage is outside of specified limits.
Possible Causes
Battery switch is not turned on
Overcharging or undercharging due to faulty alternator
Summary of Fault Correction Possibilities
Turn the battery switch on.
Replace the alternator.
Fault Codes
Page 4A-40 © 2018 Mercury Marine 90-8M0146617 eng JULY 2018