SC-1

Questions and Answers

  • M
    Michael McphersonSep 3, 2025
    Why isn't the USB-to-serial adapter showing in the communication port dropdown for my METER SC-1?
    • E
      Erica MoranSep 4, 2025
      If the USB-to-serial adapter is not showing as an option in the communication port dropdown for your METER Measuring Instruments, check that the device driver is properly installed. Try reinstalling the METER driver by downloading it and running the installer. Also, ensure the appropriate device driver is installed for third-party USB-to-serial adapter cables.
  • A
    Ashley KingSep 1, 2025
    What to do if 'Initial conductance is too high' message persists on my METER Measuring Instruments?
    • N
      nmercerSep 1, 2025
      If the 'Initial conductance is too high' message persists on your METER Measuring Instruments, close the leaf clip and shake the sensor head briskly in a vertical orientation to equilibrate. Also, check the integrity of the round rubber seal that caps the measurement chamber, as an air leak may have developed. Test for leaks by placing fresh desiccant in the desiccant chamber and leaving the sensor head undisturbed for 2–3 days. Use the diagnostics screen to check the RH of the unopened sensor head. If the RH is >10%, there is a leak.
  • A
    Ashlee CraigAug 31, 2025
    Why does downloading data from my METER SC-1 Measuring Instruments stop with a 'connection lost' error, and how can I prevent it?
    • T
      Thomas HayesAug 31, 2025
      A noisy serial connection can disrupt the connection between the Leaf Porometer Utility and the SC-1, causing data download interruptions. To resolve this, change the Leaf Porometer Utility Communication preferences by going to Edit > Preferences, selecting the Communication tab, and decreasing the Maximum Baud Rate value or increasing the Command Retries value. Click Close to save the changes.
  • D
    Deborah OrtegaAug 29, 2025
    What should I do if the conductance readings on my METER SC-1 are not as expected?
    • D
      Daniel HebertAug 29, 2025
      If the conductance readings on your METER Measuring Instruments are not what you expected, verify porometer accuracy. You can also recalibrate the sensor head, and clean the sensor head. If the Tefol n filter is wet or dirty, replace the filter.
  • M
    Miss Megan HarrisonAug 28, 2025
    Why am I getting a 'Firmware is corrupted!' error on my METER SC-1, and how do I fix it?
    • R
      Raven JosephAug 28, 2025
      A 'Firmware is corrupted!' error on your METER Measuring Instruments may occur if the firmware was not loaded properly or an update is needed. Before reloading the new firmware, download any data. Check metergroup.com/sc1-support for a new firmware version.
  • R
    Robert StevensAug 27, 2025
    What to do if I get a Sensor Head Failure error on my METER SC-1?
    • D
      Douglas PeckAug 27, 2025
      If you encounter a Sensor Head Failure error on your METER Measuring Instruments, first verify the sensor head is securely connected to the serial port receptacle. If the error persists, restart the reading. You may also navigate to the Configuration tab, select Diagnostics, and press ENTER to save a Scan record. Contact Customer Support with the Scan record results ready for review.
  • S
    Scott DavisAug 25, 2025
    How to improve the visibility of the display on METER SC-1?
    • J
      jgonzalesAug 25, 2025
      To improve the visibility of the display on your METER Measuring Instruments, you can adjust the contrast. Navigate to the Configuration tab, scroll down to Contrast, and use the UP and DOWN buttons to adjust the screen contrast level.
  • C
    Christopher ObrienAug 22, 2025
    How to fix a METER Measuring Instruments SC-1 that does not turn on?
    • A
      austinbryceAug 23, 2025
      If your METER Measuring Instruments SC-1 does not turn on, check that the batteries are inserted correctly. If it still does not turn on, replace the batteries.

Summary

1. INTRODUCTION

2. OPERATION

2.1 CONFIGURING

Steps to configure the SC-1 system date, time, and units for accurate readings.

2.2 TAKING A MEASUREMENT

Guide on how to take measurements using the SC-1 Leaf Porometer.

2.2.1 MEASUREMENT CONSIDERATIONS

Factors affecting stomatal conductance readings like light, temperature, and humidity.

2.2.2 MEASUREMENT PROCESS

Step-by-step process for taking measurements with the SC-1 Leaf Porometer.

2.3 SAVING DATA

Instructions on how to save, annotate, or discard measurement data.

2.4 VIEWING DATA

Steps to view previously saved test results on the SC-1 controller.

2.5 DOWNLOADING DATA

How to download measurement data from the SC-1 to a computer.

2.6 ERASING DATA

Procedures for erasing all stored data from the SC-1 controller or utility.

3. SYSTEM

3.1 SPECIFICATIONS

Detailed measurement and physical specifications for the SC-1 Leaf Porometer.

3.2 SC-1 SENSOR HEAD

Description of the SC-1 sensor head, its function, and components.

3.3 SC-1 CONTROLLER

Description of the SC-1 controller, its buttons, and interface.

3.3.1 TABS

Explanation of the main menus: Measurement, Data, and Configuration tabs.

3.3.2 MODES

Explanation of Auto and Manual measurement modes for the SC-1.

3.4 LEAF POROMETER UTILITY

Details on the Leaf Porometer Utility software for data management and settings.

3.5 THEORY

Explanation of the scientific principles behind SC-1 stomatal conductance measurements.

4. SERVICE

4.1 CALIBRATION

Guidance on ensuring and performing accurate stomatal conductance measurements.

4.1.1 VERIFICATION PROCESS

Steps to verify the SC-1's accuracy before taking measurements.

4.1.2 CALIBRATION PROCESS

Detailed steps for performing a user-initiated calibration of the SC-1.

4.2 MAINTENANCE

Guidelines for system inspection, parts replacement, and instrument cleaning.

4.2.1 INSTALL BATTERIES

Instructions on how to change the AA batteries in the SC-1 controller.

4.2.2 CLEAN SENSOR HEAD

Procedures for cleaning the SC-1 sensor head to maintain performance.

4.2.3 REPLACE LEAF PADS

Steps for replacing damaged or missing leaf pads on the SC-1 sensor head.

4.3 TROUBLESHOOTING

Common problems, their causes, and solutions for the SC-1 Leaf Porometer.

4.4 CUSTOMER SUPPORT

Contact information for METER customer support in North America and Europe.

4.5 TERMS AND CONDITIONS

Agreement to METER Group's terms and conditions for using the instrument.

METER SC-1 Specifications

General IconGeneral
BrandMETER
ModelSC-1
CategoryMeasuring Instruments
LanguageEnglish