840DCT EM-9538-B Rev.5
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
1.4 COMPONENT IDENTIFICATION
FRONT VIEW
With Front Panel
NOTE
• The engineering unit sticker label position is our recommended position.
• When an engineering unit is specied by the Ordering Information Sheet, the unit(s) will be shipped with the sticker
label put on the above position.
Without Front Panel
COMPONENT FUNCTION COMPONENT FUNCTION
Polarity indicator Turns on when negative value is displayed. 4-digit display Indicates present value, setting value and
scaling error. Range: 0 to 9999
BUTTON FUNCTION
D
ISP/
Used to move on to the display setting mode, to shift through setting items in
each setting mode, or shift through display digits in each setting item.
S
CALE/
Used to move on to the scaling setting mode, to shift through setting items in
each setting mode, or shift through display digits in each setting item.
S
HIFT Used to move on to the setting standby status.
U
P Used to change setting values in a setting standby mode.
Engineering unit
sticker label position
Front panel