Operation
52
Program cancel-
lation with manual
disinfection
For programs with the Drainage after disinfection parameter activated,
additional steps may be necessary for program cancellation. If there
has been no thermal disinfection, the wash water must be decon-
taminated manually.
Manual program
cancellation
During the first program phase:
Press the button and confirm the confirmation prompt Cancel
program? with Yes.
The fault messageProgram aborted by user is displayed.
There is wash water in the wash cabinet; it is not drained.
Program cancella-
tion due to fault
If the program is canceled due to a fault during the initial program
phase, the wash water is not drained. The required steps are de-
scribed under “Manual disinfection”.
Manual disinfection
Press OK to acknowledge the fault message in the list.
Press OK to acknowledge the program cancellation.
The message Please unload appears in the program sequence dis-
play.
Open the door on the infeed side.
Decontaminate the wash water by adding disinfecting agent.
Close the infeed side door.
Select the load carrier.
Select and start the Manual disinfectionprogram from the list of pro-
grams assigned to the load carrier.
The wash water is drained; another fault message is displayed.
Press OK to acknowledge the fault message in the list.
The infeed side door can be opened.