System settings
66
Press OK to confirm the message in the display.
The dispensing quantity measurement is carried out.
The process steps appear in the display, e.g., Dispenser pump active.
Once the measurement is complete, the on-screen keyboard opens.
The previously set value is displayed.
Fill the 500–1000ml measuring cylinder up to the original fill level
with the process chemical from the 100ml measuring cylinder.
Read off the required filling volume on the 100ml measuring cylin-
der.
Enter the read value using the on-screen keyboard and confirm with
OK.
The measurement results for the conversion factors are displayed,
e.g.:
Conversion factor DOS 1:
old... µl/Imp new... µl/Imp
Conversion factor flow sensor 1:
old... µl/Imp new... µl/Imp
Accept new values?
The new conversion factors are taken over by the control module with
OK; pressing retains the old conversion factors. The Set up dis-
pensing system menu reappears in the display.
Contact Miele Technical Service to carry out Set up dispensing sys-
tem if the machine dispensing systems are not equipped with suc-
tion wands.