W1113, W1119, W1203, W1213 & W1215 Clothes Washers
3.4 Fault Code F1, NTC Sensor Short-Circuited
Symptom
Should the NTC Sensor Circuit contain a short circuit, the heating is
switched off after about 10 seconds, however the program
continues. If the fault occurs with hot water operation, the machine
changes over to cold water operation.
Cause
NTC Temperature Sensor or its connections short-circuited.
Remedy
Check the NTC Temperature Sensor in the service mode.
Check the NTC Temperature Sensor for an open or short circuit.
Check the NTC Temperature Sensor resistance.
3.5 Fault Code F2, NTC Sensor Open-Circuited
Symptom
The heating switches off after approximately 10 seconds; however
the program continues.
Cause
NTC Temperature Sensor or its connections contain an open-
circuited.
Remedy
Check the NTC Temperature Sensor and circuit for an open
circuit.
Check the NTC Temperature Sensor resistance, for proper
operation at various temperatures. (Refer to Table 030-2)