EasyManua.ls Logo

Miele W1113 - 070-9 Service Mode

Miele W1113
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
71
W1113, W1119, W1203, W1213 & W1215 Clothes Washers
Table 070-9: Service Mode (Continued on Table 070-10)
SERVICE LEVEL TEST STEP
Flashing
rhythm of
Buzzer LED
Flashing
rhythm of
Soak LED
Long Short
Selection:
Press
Buzzer
button
Selection: Press
Start button
Function
tested/Machine
response
Long Short
Display
- 2
Software
version (ID)
Control/Power
module (SLT)
- - - -
Cause Fault code
-
No fault registered F 0 - -
F0
NTC temperature
sensor short-
circuited
F 1 - 1
F1
NTC temperature
sensor open-
circuited
F 2 - 2
F2
Water intake fault F 10 1 -
F10
Drainage fault F 11 1 1
F11
Water intake fault –
Hot water
F 15 1 5
F15
Excess foam
F 16 1 6
F16
Heating fault
F 20 2 -
F20
EEPROM fault, data
fault
F 41 4 1
F41
Control/power
module (SLT) and
control panel/display
module (BAE)
incompatible
F 43 4 3
F43
- 2
Fault
register
display and
deletion
Control/power
module (SLT) –
Control panel/display
module (BAE)
interface fault
F 47 4 7
F47

Table of Contents

Other manuals for Miele W1113

Related product manuals