Technical Information
77
W1113, W1119, W1203, W1213 & W1215 Clothes Washers
1 Technical Data
n/a
2 Function
2.1 Heater Relay - Switching
If a selected program requires higher temperature, than the
temperature of the water supply; the water will be heated.
For the heater to operate the Water Level Sensor must have
detected at least a Level 1 position. The signal is then provided to
the Power Electronic which energizes the Heater Relay (coil).
When the Heater Relay is energized, it’s contacts close and supply
the Heater Element with power.