Technical Information
63
W1113, W1119, W1203, W1213 & W1215 Clothes Washers
Program Position Option(s)
Flashing Rhythm
Of Buzzer LED
Selection Selection
Flashing
Rhythm of Soak
LED
Long Short Buzzer Button Start Button Long Short
Display
Tachogenerator - 1 P1
Imbalance sensor and
tachogenerator
- 2 P2
2 1
Imbalance and
load measurement
Displacement sensor
(load sensor) and
tachogenerator
- 3 P3
2 2 Water Intake Sys.
USA (Do Not Change) - - P0
LED Display – OFF - - P0
2 3 Digital display
LED Display – ON - 1 P1
Not active - - P0
2 4 Time left display
Active - 1 P1
Not active - - P0
2 5 Delay start
Active - 1 P1
Frontloader - - P0
2 6 Model version
Toploader - 1 P1
None - 1 P1
Load - 2 P2
Dispensing - 3 P3
2 7
Load / Dispensing
display
Load and dispensing - 4 P4
OFF
- -
P0
2 8 Drum Light
ON
-
1 P1
7 program sequence
LEDs
- 1 P1
2 9 Fascia type
6 program sequence
LEDs
- 2 P2
Table 070-8: Programming Functions (continued from Table 070-7)