3-8
7
Change the reference length in the B direction (horizontal direction)
with the jog key or .
If you change the reference length in the B direction, the distance compensation value (B)
will be cleared.
8
Press the key to determine
the reference length in the B direction.
9
Select the plotting position of the
distance compensation adjustment
pattern with jog key or .
Offset all the line segments (AR, AL and B) to inside of the sheet.
10
Press the key.
The plotter plots an adjustment pattern.
If no sheet is placed on the plotter, or the sheet size is too small to plot the reference
length on, the plotter will not conduct plotting. In this case, if you press the key,
the plotter will enter the state that permits inputting compensation values without plotting.
11
Upon completion of plotting, the plotter
will display the current compensation
values.
12
Measure the OFF lines of AR and AL.
Move down the clamp lever to the rear and remove
the sheet to measure.
DRAW SH I F T = 0mm
ENTER/HOLD
DRAW SH I F T = 1 0mm
ENTER/HOLD
ENTER/HOLD
AR=0 . 0 AL